580-Ton Tested. Earthquake & Health Protection in One.

Japan’s first shelter to pass a 580-ton compressive crushing test!
Our “WNI-SHELTER” is a new disaster shelter that can support both earthquake protection and health.

For general wooden-frame housing, including three-story houses.



For light-gauge steel-frame buildings and housing complexes
Office buildings and mid-rise condominiums.



New product:
Heavy-duty and strong specifications
For heavy-gauge steel-frame buildings and industrial facilities
Warehouses and factories.



In 2011, when the Great East Japan Earthquake occurred, about 10,000 earthquakes occurred. Five years later, the Kumamoto earthquake in 2016 caused about 6,500 earthquakes (including 192 seismic intensity(*) 4 and 8 seismic intensity 5 or higher), in 2017 about 2,000 (including 78 seismic intensity 4 and 8 seismic intensity 5 or higher), in 2018 about 2,000 (including 67 seismic intensity 4 and 11 seismic intensity 5 or higher), and in 2019 In 2019, approximately 1,560 earthquakes (of which 40 were intensity 4: 40, 9 were intensity 5 or lower: 9) occurred in the small country of Japan, and the fear and anxiety only continues.
Over the past 10 years, Japan has experienced an average of about 2,000 earthquakes per year, which means that people are at risk in about 5 locations per day.
*The term “seismic intensity” indicates the degree of shaking at a particular location.
Crumb-proof earthquake shelter!

80% of the deaths in the 2016 Kumamoto earthquake were due to “crushing death”. (To be exact, their lungs were crushed and they could no longer breathe.) Our earthquake shelters have passed the 580-ton load-bearing test and are essentially crush-proof. In fact, the shelter was able to withstand the 580-ton load-bearing test and an internal pressure of 3.0 atmospheres.
No other shelter in the history of Japan has such excellent earthquake resistance.
Translated with www.DeepL.com/Translator (free version)


Our shelters passed a third-party quality performance/compression test of approximately 580 tons. Even under this load, our shelter was able to withstand, leaving only 6mm of distortion.
(The testing machine could not apply more than 580 tons of force, so the test ended there.) Based on the testing agency’s data, our shelter should easily pass the 700-ton test as well! While conventional general shelters could only withstand 30-40 tons, our product is far more durable: it is designed to be powerful enough to withstand forces in excess of 500 tons, and it has passed load-bearing, seismic strength, and compression-crushing tests conducted by public and third-party organizations, which is an endorsement of its safety.





Can be installed in tight spaces!

Can be installed so as not to obstruct workflow or evacuation routes!

Can be installed at sites with low ceilings!

200 Ton Test Pass
Certificate

580 Ton Test Pass
Certificate

Confirmation screen when the load capacity passes 580 tons in the load capacity test.

Our products are individually handmade in our own factory, ensuring that they are tough enough to withstand various inspection standards. Each product is available in standard sizes, but as a manufacturer, our strength lies in our ability to respond to custom orders to meet the needs of our customers. Our staff in charge will listen to your requests and propose the most suitable product for your site environment, location, and situation.
All of our products are manufactured in Japan, so you can be assured of their quality. In fact, even every single bolt is made in Japan. We pursue careful manufacturing that you can rely on. Another major difference from other companies is that to ensure the strength of our shelters, we conduct internal pressure tests to ensure that they can withstand not only external loads but also external pressure from the inside.
We also pursue thorough certainty, daring to conduct strength tests from the inside to the outside.


We offer installation services in a variety of locations, from high-rise buildings to single-family homes, apartments, condominiums, buildings, and public facilities. Our expert staff checks the delivery route and location in advance to ensure smooth delivery.

In case of emergency, evacuate to the shelter with your family to protect your personal safety!
Shelter Features : Shelters to Protect Lives
– Our shelters are designed to withstand loads in excess of 580 tons, having undergone a 580-ton load-bearing test.
– As a result, the shelter was able to withstand the load leaving only about 6mm of distortion.
– Since the shelter is box-shaped, it provides 360-degree protection against not only house collapse, but also furniture and appliances being ejected by earthquakes, providing peace of mind for your family.


Health Apparatus for Daily Use
Hyperbaric Oxygen Room Function – Health Equipment
– This shelter has the same function as oxygen capsules that help athletes recover from injuries and illnesses quickly. While conventional capsules are used with one person lying down at a time, our room-type shelters are more spacious.
– The bottom surface area is the same as that of a capsule and can supply up to 1.9 atmospheres, which can be used for daily health care (anti-aging, promoting recovery from fatigue, etc.).
– Currently, hyperbaric oxygen is attracting attention not only from sportspersons but also from health-conscious people.

Effects of oxygen rooms Your results might vary.
❶ Recovery from fatigue: Lactic acid is said to cause muscle fatigue and soreness. Oxygen breaks down and eliminates lactic acid and other substances that cause fatigue. When fresh oxygen circulates through the human body, it reinvigorates exhausted muscle cells, thereby alleviating fatigue. Therefore, oxygen supplementation is said to offer relief in the case of muscle soreness caused by strenuous exercise as well as both chronic and light fatigue.
❷ The brain and oxygen: Approximately 25% of the body’s oxygen is said to be delivered to the brain. The brain is the site of many capillaries, so adding dissolved oxygen to the brain by using a high-pressure environment revitalizes the brain, which means that oxygen supplementation leads to a clear head and improved focus.
❸ Eyestrain: There are many capillaries in the eyes as well. When the eyes are continuously abused, it causes tonic muscle contraction that worsens the flow of blood in the eyes, ultimately causing a lack of oxygen. Oxygen supplementation therefore alleviates eyestrain and makes it easier to see.

Effects of oxygen rooms

Anti-aging

Prevention and
alleviation of dementia

Sports and Athletics

Beauty

Early recovery from
fractures and other injuries

Alleviation of insomnia
and other sleep
disorders

Relief of overwork and
fatigue

Diet

They are designed to blend seamlessly into your interior while providing safety and everyday ease of use.
From child-safe, soft designs to smart storage solutions, our shelters transform living spaces into functional and beautiful living spaces.

・The appearance goes well with interior design (and designs that match sofas and curtains are available).
・Our shelters feature a soft design so young children who bump into them will not get hurt.













It is also possible to seamlessly remodel a house when installing a shelter.
For example, a shelter can be seamlessly integrated into a new wall as shown in the figure below.
– The shelter fits in the space enclosed by the red line, so the dead space above the shelter can be effectively utilized as a loft or storage space.
Options such as TVs, air conditioners, sofas, and flooring are also available to transform the shelter into a normal space that can be used on a daily basis.





We offer a wide variety of interior colors.
Please contact us for more information.

World Net International designs, assembles, and paints every shelter at its own factory, fully customizing the shape, size, and entrance positions (multiple entrances possible) of each product in response to customer needs.




| Product Name | WNI-SHELTER |
|---|---|
| Product type | Earthquake shelter |
| Sizes | • S size: 2,400 (W) x 800 (D) x 1,600 (H) • M size: 2,400 (W) x 1,300 (D) x 1,600 (H) • L size: 2,400 (W) x 2,000 (D) x 1,600 (H) *Unit: mm *In addition to the standard sizes (S, M, and L), customized sizes are available |
| Outside dimensions | ![]() ❶Depth:S 800mm/M 1,300mm/L 2,000mm ❷Height:S 1,600mm/M 1,600mm/L 1,600mm ❸Width:S 2,400mm/M 2,400mm/L 2,400mm |
| Weight | Cabin: S size: 450 kg, M size: 510 kg, L size: 680 kg |
| Product Name | WNI-SHELTER |
|---|---|
| Product type | Earthquake shelter |
| Sizes | • S size: 2,400 (W) x 800 (D) x 1,600 (H) • M size: 2,400 (W) x 1,300 (D) x 1,600 (H) • L size: 2,400 (W) x 2,000 (D) x 1,600 (H) *Unit: mm *In addition to the standard sizes (S, M, and L), customized sizes are available |
| Outside dimensions | ![]() ❶Depth:S 800mm/M 1,300mm/L 2,000mm ❷Height:S 1,600mm/M 1,600mm/L 1,600mm ❸Width:S 2,400mm/M 2,400mm/L 2,400mm |
| Weight | Cabin: S size: 450 kg, M size: 510 kg, L size: 680 kg |
| Product Name | O₂-SHELTER (Selectable from 1.1 to 1.9 atmospheres) |
|---|---|
| Product type | Earthquake shelter + hyperbaric oxygen capsule |
| Sizes | • S size: 2,100 (W) x 780 (D) x 1,350 (H) • M size: 2,300 (W) x 850 (D) x 1,500 (H) • L size: 2,600 (W) x 1,200 (D) x 1,500 (H) • Control unit (analog type): 410 (W) x 260 (D) x 330 (H) • Control unit (microcontroller type): 460 (W) x 310 (D) x 870 (H) *Unit: mm *In addition to the standard sizes (S, M, and L), customized sizes are available. |
| Outside dimensions | ![]() ❶Depth:S 780mm/M 850mm/L 1,200mm ❷Height:S 1,350mm/M 1,500mm/L 1,500mm ❸Width:S 2,100mm/M 2,300mm/L 2,600mm Control unit ![]() |
| Weight | • Cabin: S size: 450 kg, M size: 510 kg, L size: 680 kg • Control unit: analog: 11 kg, microcontroller type: 35 kg |
| Air pressure in the shelter | • The microcomputer control unit allows for automatic setting 1.1 to 1.9 atmospheres. • The shelter is equipped with a timer and can be controlled from a control panel outside the shelter as well as inside the shelter. |
| Product Name | O₂-SHELTER (Selectable from 1.1 to 1.9 atmospheres) |
|---|---|
| Product type | Earthquake shelter + hyperbaric oxygen capsule |
| Sizes | • S size: 2,100 (W) x 780 (D) x 1,350 (H) • M size: 2,300 (W) x 850 (D) x 1,500 (H) • L size: 2,600 (W) x 1,200 (D) x 1,500 (H) • Control unit (analog type): 410 (W) x 260 (D) x 330 (H) • Control unit (microcontroller type): 460 (W) x 310 (D) x 870 (H) *Unit: mm *In addition to the standard sizes (S, M, and L), customized sizes are available. |
| Outside dimensions | ![]() ❶Depth:S 780mm/ M 850mm/L 1,200mm ❷Height:S 1,350mm/ M 1,500mm/L 1,500mm ❸Width:S 2,100mm/ M 2,300mm/L 2,600mm Control unit ![]() |
| Weight | ・Cabin: S size: 450 kg, M size: 510 kg, L size: 680 kg ・Control unit: analog: 11 kg, microcontroller type: 35 kg |
| Air pressure in the shelter | • The microcomputer control unit allows for automatic setting 1.1 to 1.9 atmospheres. • The shelter is equipped with a timer and can be controlled from a control panel outside the shelter as well as inside the shelter. |
Please feel free to make an inquiry below if you have any questions related to the purchase.
Please fill out the form below and click To Confirmation button to transmit your inquiry.
A staff in charge will get in touch with you shortly.
Asterisks (*) indicate fields required to complete this contact form.


In-house development and manufacturing
当社シェルターは国内工場で自社開発・製造を行っており、一台ずつハンドメイドでの製造を行っております。
また、地震の際に求められる耐震強度についても、50トン・75トン・100トン・160トン・200トン・580トンの耐荷重圧縮試験に合格した『証明書』付きの製品となります。各製品共に既定のサイズ設定は設けて おりますが、ハンドメイド製造ならではともいえる、お客様のご要望に合わせたサイズやデザインのカスタマイズ注文にも対応しております。業界初の全国施工も承ります。